peewee | 03-28-2009 | comment profile send pm notify |
Gotta question i have a 40m z boom with 4.4 pipe ultra lite boom 24volt can i put 5 inch pipe insteed of 4.4 (to damn expensive) it has little blocks in the holders just wondering |
||
Schwinger | 03-28-2009 | reply profile send pm notify |
Phone their engineering department, you will learn new swear words in german. (After they quit laughing) |
||
rich3317 | 03-28-2009 | reply profile send pm notify |
I feel for you. Back in the 80ds there was a few 50 meter with 4.5 pipe. i was told that they got the ok to use 5". Some years later one of them had a boom break :((( I only heard that in the court room the builder said they never ok that! It had a very SAD ending. |
||
PUMBO | 03-28-2009 | reply profile send pm notify |
Plain and simple: "NEIN!!!!" (NO!!!!) |
||
peewee | 03-29-2009 | reply profile send pm notify |
well crap there goes my next raise thanks for the info |
||
Old School 2 | 03-29-2009 | reply profile send pm notify |
you can go to 4.6 pipe no bigger. |