kiwi | 07-30-2016 | comment profile send pm notify |
hi don't know if you can help I run a 26x4 scwhing 1994, just lately when you turn on pump rock valve, will stay where it is ram will go up and back down then rock will change over , but wont go over all the way, and on the first stroke, it labours a bit, would the seals need changing on the end of the main pumping rams , gland seals was done two years ago any help would be great thanks |
||
gboom | 08-09-2016 | reply profile send pm notify |
you are most likely dealing with some stuck spools in the system, whats the condition of your oil? And given the age of the pump, some worn out components |
||
kiwi | 08-10-2016 | reply profile send pm notify |
hi all sorted today changed, check valves there are four, put three new ones on , and now good as gold |